SKF TMEA 1P/2.5 Instrucciones De Uso página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
a) Adjust the measuring units to
the 9 o'clock position with the
aid of the spirit levels (fig. 18).
b) Confirm the measurement
by pressing
c) Follow the circle symbol on
the display and rotate the
measuring units to the 3
o'clock position (fig. 19).
d) Confirm the measurement
by pressing
e) Follow the circle symbol to the
12 o'clock position (fig. 20).
f) Confirm the measurement
by pressing
Note!
By pressing the
"previous" button, you
will reverse the process
in order to repeat any of
the measurement steps
or to adjust any of the
machine dimensions.
TMEA 1P/2.5 / TMEA 1PEx
.
Fig. 18. Adjust to the 9 o'clock
.
.
Fig. 19. Rotate to the 3 o'clock
Fig. 20. Back to the 12 o'clock
Shaft Alignment Tools
position
position
position
23

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Tmea 1pex

Tabla de contenido