Special Maintenance Work

Check for leaks again after servicing and/or replacing parts.
We recommend having all maintenance jobs carried out by
Dräger. Keep a record of the servicing (see "Record Card" on
page 36).
Replacing the Gloves
Pull the rubber ring off the over-
glove if necessary.
Pull off the overglove.
Lift the edge of the rubber cuff
with your fingertips and press the
supporting ring and the glove out
of the sleeve with the ball of your hand.
Pull old glove off support ring and arm cuff
Pull a new glove onto the support-
ing ring and the arm cuff until the
bulge at the glove exceeds the
upper edge of the supporting
ring.
Push glove with support ring and
sleeve cuff through opened zip
fastener and into sleeve of chemical protective suit, then
push glove through rubber flap at edge of sleeve.
Check and align: the left-hand glove belongs in left sleeve,
etc. The palm of the glove points towards the sleeve seam.
The long axis of the elliptic supporting ring is parallel to the
palm.
Reach into the sleeve and press the glove with support ring
and arm cuff (if applicable) into the rubber flap until the bot-
tom edge of the support ring rests against the edge of the
rubber flap.
Install overgloves, if necessary:
Pull the shaft of the overglove over both bulges of the glove
arm ring and fix it with the associated rubber ring.
NOTICE
You can wear the knitted overgloves without further securing
means (the knit band fits closely to the wrist) or pull them
over both bulges of the glove arm ring and fix them with the
associated rubber ring.
1) The sleeve cuff is not part of the standard equipment.
Replacing the Protective Boots
The original squeezing clip for fastening the boots may only be
installed with suitable tools. If necessary, send the chemical
protective suit to Dräger for repair.
Otherwise, proceed as follows:
Roll up the trouser leg until you
see the shaft of the protective
boot.
Fold down protective strip.
Use a screw driver to pry open the
squeezing clip and remove the
clip.
Take care not to damage the chemical protective suit.
Remove old sealing compound residues from leg of trou-
sers. Clean the upper shaft part of the protective boot and
wipe it with a lint free cloth soaked with white gas for clean-
1)
.
ing purposes.
Remove protective strip and rubber ring, then draw support
ring out of protective boot.
Remove old protective boot from leg of trousers and insert
new boot.
Press the supporting ring into the new protective boot and
pull the rubber ring over the shaft of the protective boot so
that it fits flush to the shaft.
Align the edges of the boot shaft and the rolled-up trouser
leg so that they are flush.
Slide screw clamp over edge of trouser leg and centre it
over support ring.
Clamp points to heel of protective boot. Slide protective
strip under clamp and tighten clamp with screwdriver.
Seal the protective boot/trouser leg area with the Sealant
repair set.
Affix padded strip to clamp, fold up protective strip and roll
down trouser leg.
Replacing the Valve Disc
Remove protective cap and old
valve discs. Do not damage peg.
Fit new valve discs and check suit
valve for leaks.
Fit protective cap.
Replacing the Valve Seat
Dismount the suit valve:
Loosen and remove the threaded
ring using hexagon key
16 28 089.
Pull off the slide ring and the seal
and replace the defective valve seat.
Install the valve disc and check the chemical protective suit
for leaks.
Fit protective cap.
2) Follow the separate Instructions for Use of the product.
2)
27