Unit Control
[Notes]
Move the cursor to the desired option and "Enter" will be displayed at the lower left side of the LCD,
reminding you that you are allowed to access to the submenu by pressing the OK key
At the FUNCTION page, when the setting of some function option is changed and needs to be
memorized, then in case of power failure it will be saved automatically and resume upon power recovery.
No�
Full Name
Running mode
1
setting
2
Control state
Water out
3
temperature control
4
Quiet mode
5
Quiet timer
Weather-
6
dependent mode
7
Holiday release
8
Weekly timer
9
Clock timer
10
Temperature timer
11
Floor debug
12
Emergency mode
13
Holiday mode
14
Thermostat
15
Assistant heater
16
Other heater
17
Chassis heater
Plate heat
18
exchanger heater
19
Floor config
20
Radiator config
21
FCU
22
Remote sensor
23
Air removal
24
Address
25
Gate-controller

Function Settings

Displayed Name
Mode
Ctrl. state
T-water out /T-room
High temp./Normal
T-water ctrl
Quiet mode
Quiet timer
Weatherdepend
Holiday release
Weekly timer
Clock timer
Temp. timer
Floor debug
Emergen. mode
Holiday mode
Thermostat
With/Without
Assis. heater
Off /one/two
Other heater
With/Without
Chassis heater
Plate heater
Floor config
With/Without
Radia config
With/Without
FCU
With/Without
Remote sensor
With/Without
Air removal
Address
Gate-Ctrl.
Range
Default
Cool/Heat
Heat
T-water
out
Normal
temp.
temp.
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
On/Off
Off
Without
Off
Without
On/Off
On
On/Off
On
Without
Without
Without
Without
On/Off
Off
[1-125]
1
[127-253]
On/Off
Off
10
.
Remarks
/
"T-Room" is available only when
"Remote Sensor" is set to "WITH".
If "Floor config" is set to "With", the
control is defaulted to be "Normal
temp.". If not, then the control is
defaulted to be "High temp.".
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
If "Floor config" is set to "With", the
control is defaulted to be "Normal
temp.". If not, then the control is
defaulted to be "High temp.".
/
If "FCU" is set to "With", the range
of water out temperature for cooling
(WOT-Cool) is 7-25 °C,and the default
is 7°C. If not, then the range of the
water out temperature for cooling
(WOT-Cool) is 18-25°C,and the default
is 18°C.
When it is set to "Without", the "Control
state" will be automatically changed to
"T-water out".
/
/
/