Clock Timer - Gree EVO Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

than "End time". Similarly, the preceding period must be earlier than its following period.
When "Weekly timer" has been set successfully, by changing "FCU" , "Ctrl. state", or "T-water ctrl.", then
the temperature set point for "Weekly timer" will be automatically changed to the set point of last setting. For
instance, if "Heat" is set for Monday of "Weekly timer", "FCU" is set to "With" and the "T-water out" is 20°C, by
resetting "FCU" to "Without", then "T-water out" will be the value of last setting. In this case, if FCU is disabled
for last setting, then "T-water out" will be the default value (18°C).
At the "WEEKLY TIMER" setting page there are totally three setting types for each day
"√": it indicates once the Week Timer is activated, the timer on this day is effective and will not be affected
by the "Holiday" mode.
"×": it indicates even if the Week Timer is activated, the timer on this day is ineffective.
"Holiday Mode": it indicates when the Week Timer is activated but "Holiday Mode" is not activated, then
the timer on this day is effective; when "Holiday" is also activated, the timer on this day is ineffective.
Temperature Setpoint
The control is able to decide the temperature type and temperature range based on the current "Clock
Timer", "FCU", "T-water Ctrl�", and "Ctrl� state" settings. See the followings for more details.
Set
Ctrl� state
Mode
Cool
T-water out
Heat
Cool
T-room
Heat
3�3�2�9 Clock Timer
This function will make the unit run with certain modes in certain periods within a day based on the user's
actual needs.
[Operation Instructions]
1. At the homepage, by pressing the Function key
where "Clock timer" is, after that, press OK key
16:15
Start time
2. At the CLOCK TIMER setting page, by the Left/Right key
then by the Up/Down key
3. When this setting is concerned about time value, by pressing the Function key no. 1
Object
Water out temperature
for cooling
(With FCU)
High temp.
Water out temperature
for heating
Normal temp.
Room temperature for
cooling
Room temperature for
heating
2013-01-04
Friday
Mode
WT-heat
Heat
End time
08:30
Save
configure it.
Range
7-25°C
18-25°C
(Without FCU)
25-60°C
25-55°C
18-30°C
18-30°C
access to the FUNCTION page, and then locate
to go to the COLCK TIMER setting page.

CLOCK TIMER

17:30
15
Unit Control
Default
Accuracy
7°C(With FCU)
18°C(Without FCU)
45°C
35°C
24°C
20°C
select the desired parameter and
alternately set
1°C
1°C
1°C
1°C
1°C

Publicidad

Tabla de contenido
loading