Gree EVO Serie Manual De Instrucciones página 28

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Unit Control
[Notes]
The real-time error will show on the control. Taking Error 2 in the above figure for example, when it is
recovered, it will disappear and be replaced by Error 3, and other errors follow the same way.
If the total no. of errors exceed six, other errors should be viewed by switching pages through "Last"
and "Next"
.
Any one among "IDU auxiliary heater 1 error", "IDU auxiliary heater 2 error"occurs, the control will
beep until this error has been cleared.
See the following table for error description.
No�
1
Ambient temperature sensor error
2
3
Discharge temperature sensor error
4
5
6
Compressor internal overload protection
7
8
9
10
11
Heat pump-water pump protection
12
Swimming pool-water pump protection
13
Incorrect capacity DIP switch setting
14
Communication error between indoor and outdoor unit
15
16
17
18
19
Heat exchanger-leaving water temperature sensor error
20
Auxiliary heater-leaving water temperature sensor error
21
Heat exchanger-entering water temperature sensor error
22
Swimming pool-entering water temp sensor
23
Swimming pool-leaving water temp sensor
24
Swimming pool-water temp sensor
25
26
27
28
29
Welding protection of the auxiliary heater 1
30
Welding protection of the auxiliary heater 2
31
Under-voltage DC bus or voltage drop error
32
33
34
35
Full Name
Defrost temperature sensor error
Suction temperature sensor error
Outdoor fan error
High pressure protection
Low pressure protection
High discharge protection
Refrigerant loss protection
Drive communication error
High pressure sensor error
Enthalpy-enhancing sensor error
Low pressure sensor error
Remote room sensor 1
Remote room sensor 2
Heat pump-water flow switch
Swimming pool-water flow switch
Over-voltage DC bus
AC current protection (input side)
IPM defective
PFC defective
Displayed Name
Ambient sensor
Defro. sensor
Disch. sensor
Suction sensor
Outdoor fan
Comp. overload
High pressure
Low pressure
Hi-discharge
Refri-loss
HP-pump
Swimming-pump
Capacity DIP
ODU-IDU Com.
Drive com.
HI-pre. sens.
En. senser
LOW-pre. Sens.
Temp-HELW
Temp-AHLW
Temp-HEEW
T-Swimming in
T-Swimming out
T-Swimming
T-Remote Air1
T-Remote Air2
HP-Water SW
SW-Water SW
Auxi. heater 1
Auxi. heater 2
DC under-vol.
DC over-vol.
AC curr. pro.
IPM defective
FPC defective
26
Error Code
F4
d6
F7
F5
EF
H3
E1
E3
E4
P2
E0
c5
E6
P6
Fc
F8
dL
F9
dH
F3
EC
F1
EH
EH
PL
PH
PA
H5
Hc

Publicidad

Tabla de contenido
loading

Tabla de contenido