Unit Control
It can be set to "On" or "Off" no matter whether the unit is in operation or not.
Once it is activated, it should be deactivated manually or by Quiet Timer.
It will not memorized and defaulted to be off upon power failure.
It will be deactivated when the unit is turned off.
3�3�2�5 Quiet Timer
When running noise is too high at some specific timer periods, this function enables the unit run quietly at
this time period.
[Operation Instructions]
1. Go to the FUNCTION page and locate "Quiet timer", then, access to the QUIET TIMER setting page.
2. At the QUIET TIMER setting page, select "Start time" or "End time" through the Left/Right keys
and then configure the desired time through the Up/Down keys
3. When the mode setting is finished, then by pressing "Save", a pop-up window will pop up to remind if you
are determined to save this setting. If so, press the "OK" key
save this setting.
4. When the setting is saved, the control then will back to the FUNCTION page and the cursor will be where
the "Quiet timer" option is, then by the Up/Down key
16:15
[Notes]
Once it is activated, it should be deactivated manually.
This setting will be memorized upon power failure.
The saved "Start time" and "End time" will be memorized upon power failure.
It is configurable no matter whether the unit is in operation or not.
3�3�2�6 Weather-dependent Mode
For areas with large change of diurnal temperature, in order to avoid the user to set the leaving
water temperature or room temperature too often, this function will adjust automatically depending on the
environmental temperature.
[Operation Instructions]
Go to the FUNCTION page and locate Weather dependent Mode, then, configure it through the Up/Down
key
, "On" or "Off".
[Notes]
Once it is activated, it should be deactivated manually.
This setting will be memorized upon power failure.
At the "Parameter View" page, it is able to check the set point at the Weather dependent Mode.
When it is activated, it is allowed to set the room temperature but the set point does not take effective.
However, when it is deactivated, the unit will run according to this set point.
It can be set to "On" or "Off" no matter whether the unit is in operation or not, but be activated only when
2013-01-04

Start time

08:30
Minute
Save
. If not, press the "Cancel" key
, it can be set to be "On" or "Off".
QUIET TIMER
Friday
End time
17:30
12
.
to not