TEMP� TIMER is judged by the timer value.
During the setting, the temperature set point which is set manually always takes precedence.
3�3�2�11 Floor Debug
This function will make the unit to perform periodic preheating to the floor for the initial run once floor coils
have been installed.
[Operation Instructions]
1. At the homepage, by pressing the Function key
where "Floor debug" is, after that, press OK key
16:15
Segments
Segment time
2. At the FLOOR DEBUG setting page, by the Left/Right key
then by the Up/Down key
temp", "ΔT of segment", and "Segment time", as listed in the following table.
No�
Full Name
1
Segments for floor debug
2
First temperature for floor debug
Segment temperature difference for
3
floor debug
4
Segments duration for floor debug
3. After the above setting is finished, by pressing the function key no.2
dialog box will pop up, reminding "Start the Floor Debug Mode now?". If so, press the "OK" key
"Floor debug" has been activated, by pressing the function key no.2
reminding "Stop the Floor Debug Mode now?" If so, press the OK key
go on.
[Notes]
This function can be activated only when the unit is OFF. When it is intended to activate this function
with the unit being ON, a dialog box will pop up, warning "Please turn off the system first!".
When this function has been activated, it is unable to turn on or off the unit. In this case, when pressing
the ON/OFF key
, a dialog will pop up, warning "Please disable the Floor Debug Mode!".
When this function has been set successfully, "Timer week", "Clock timer" and "Temp timer" will be
deactivated.
"When "Floor debug" mode has been activated, Both "Emergen�mode" and "Holiday mode" are not
allowed to be activated, or a dialog box will pop up, warning "Please disable the Floor Debug Mode!".
2013-01-04
Friday
Period 1 temp △T of segment
1
12H
Start
configure it. The configurable parameters include "Segments", "Period 1
Displayed
Name
Segments
Period 1 temp
ΔT of segment
Segment time
access to the FUNCTION page, and then locate
to go to the FLOOR DEBUG setting page.
FLOOR DEBUG
25℃
Range
1~10
25~35°C/77~95°F
2~10°C/36~50°F
0~72H
17
Unit Control
5℃
select the desired parameter and
Default
Accuracy
1
25°C/77°F
5°C/41°F
0
activate this function and a
, a dialog box also will pop up,
; if not, press "Cancel"
1
1°C/1°F
1°C/1°F
12H
. Once
to