Gree EVO Serie Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

water" is adopted, then the temperature set point should be 30 .
It will quit when the thermostat effectively works ("Cool" or "OFF" operation).
When this setting is saved successfully, it will be memorized upon power failure.
This function can be activated only when the unit is OFF, or a dialog box will pop up, warning "Please
turn off the system first !".
When it is activated, the ON/OFF key
"Please disable the Holiday Mode !".
Under the Holiday mode, "Floor debug" and "Emergen� mode" cannot be activated, or a dialog box will
pop up, warning "Please disable the Holiday Mode !".
3� 3�2�14 Thermostat
When the thermostat has been installed, it can be used to control the run mode of the unit . Both "Cool" and
"Heat" modes are available.
[Operation Instructions]
1. Locate where "Thermostat" is at the FUNCTION page.
2. By pressing the Up/Down key
control follows the running mode of the thermostat and is not allowed to set the running mode; when it is "Off",
the control follows the running mode set by itself.
[Notes]
When "Floor debug" or "Emergen� Mode" is activated, then the control will not receive signals from the
thermostat.
If "Thermostat" is set to "On", the control will automatically disable some functions concerning timer, and
run in accordance with the mode set by the thermostat. In this case, the running mode is unchangeable and the
ON/OFF key
operation of the control is ineffective.
When this setting is saved successfully, it will be memorized upon power failure.
The state of the Thermostat can be changed when the unit is turned off.
3�3�2�15 Assistant Heater(Assis� Heater)
There are three options for the assistant heater: " Off", "one" or "two".
[Operation Instructions]
Go to the FUNCTION page and locate "Assis� Heater", then, configure it through the Up/Down key
, "Off/1/2".
[Notes]
It will be memorized upon power failure.
3�3�2�16 Other Heater
It can be configured to "With" or "Without" through the wired controller.
[Operation Instructions]
Go to the FUNCTION page and locate Other heater, then, configure it through the Up/Down key
, "With" or "Without".
[Notes]
●It will be memorized upon power failure.
3�3�2�17 Chassis Heater
The user will decide if to activate or deactivate the chassis heater. Generally it is suggested to activate it
under low environment temperature to prevent the chassis from being frozen.
[Operation Instructions]
Go to the FUNCTION page and locate "Chassis Heater" then, configure it through the Up/Down key
, "On" or "Off".
operation is disabled, or a dialog box will pop up, warning
, Thermostat can be set to "On" or "Off". When it is "On", the
19
Unit Control

Publicidad

Tabla de contenido
loading