4. Installation
Install the unit within an enclosed compartment of
the vehicle so that it is protected from environmental
influences. Use the lugs provided on the unit for
mounting it in a suitable place.
The IG502-E is accommodated in a housing of
type of protection IP 20. The connector is of class
of protection IP 00.
If the control unit is mounted at an inaccessible
position, it is advisable to install an additional
illuminated pushbutton on the dashboard as a fault
indicator and functional control element
(see Fig. 5).
The accessories required for the lubrication system
such as the cable set, cycle or pressure switch
can be seen from the Vogel catalog 1-9420,
1-9430.
Mounting lugs (Fig. 2)
4.1
Electrical connections
PS/CS
pressure or cycle switch
15
plus pole on-board system
+M
pump motor
+SL
external signal lamp
DK/M
external pushbutton (timer operation)
counter input (counter operation)
31
ground
Z
ignition lock
PS/CS
15
DK/MK
M
SL
M
Terminal connection diagram (Fig. 3)
Page 14
Operating Instruction Universal Control Unit IG502-E
pressure or cycle
switch PS / CS
+M pump motor
Cable set receptacle housing (Fig. 4)
5A
31
SL
Z
15
30
Electrical connection of external illuminated
pushbutton (Fig. 5)
Contents
Chapter
Central
4
Lubrication
15 + on-board system
DK / MK
31 ground
signal lamp +SL
tab receptacle
Order No.: 177-100-065
31
DK / MK