Monitoring With Pressure Switch - Vogel IG502-E Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
8.6

Monitoring with pressure switch

Only in centralized lubrication systems
for greases of NLGI classes 00 and 000!
The IG502-E is programmed by the manufacturer
for monitoring of the system via a pressure switch
COP = PS. If the monitoring function has been
disabled, see section 7.3.
If possible, the pressure switch should be installed
downstream of the last distributor in the main line.
It monitors the pressure build-up in the system
during the CONTACT time.
2
3
4
Installation and electrical connection
of pressure switch (Fig. 7)
Page 26
Contents
Operating Instruction Universal Control Unit IG502-E
2
5
M
31
15
6
2
1 Control unit IG502-E
2 Pump unit with lubricant reservoir
3 Main line
4 Distributor
5 Pressure switch
6 Friction points
Chapter
Central
8
Lubrication
1
31
15
PS/CS
F
On-board system

Publicidad

Tabla de contenido
loading

Tabla de contenido