Changing The Code; Programming Ranges; Display Areas - Vogel IG502-E Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
7.5

Changing the code

The code set by the factory has now
been cleared, and the new value is valid.
Note down the new value and keep it in
a safe place. If you forget your code, parameters
can no longer be programmed. In such a case,
the control unit has to be returned to the
manufacturer for re-coding.
7.6

Programming ranges

Function
Programming range
Pause time
0.1 h to 99.9 h
Pump running time
0.1 min to 99.9 min
Impulses
1 to 999
7.7

Display areas

Function
Display areas
Pause time
0.1 h to 99.9 h
Pump running time
0.1 min to 99.9 min
Impulses
1 to 999
Error hours
0.1 h to 99999.9 h
Operating hours
0.1 h to 99999.9 h
Step
Key
1
Press for more than 2s
2
Operate appropriate
key until
3
Press briefly
(to confirm code)
4
Press briefly
(to confirm old code)
5
Operate appropriate
key until
6
Press briefly
7
Press for more than 2s
Page 24
Contents
Operating Instruction Universal Control Unit IG502-E
Display
Display flashes
(code 000 factory setting)
Code number is displayed
(321 = factory setting)
Display flashes
Display flashes
(code 000 factory setting)
Desired new code is set
Example: 666
To confirm new code
New code is saved to memory, and the display goes out.
Chapter
Central
7
Lubrication

Publicidad

Tabla de contenido
loading