10.3

Block operation

When no signal from the cycle switch is
received, the control unit responds by
activating the block mode of operation.
10.4
Delayed signal from cycle switch
No signal from cycle switch during pump running
time
normal operation is aborted
15 min block interval begins with inquiry of cycle
switch
Signal from cycle switch during 1st block interval
block operation is aborted
Paue interval is continued up to the end of the
regular preset pause time
Signal from cycle switch during 2nd pump running
time
block operation is aborted
Regular preset pause time begins
Signal from cycle switch during 2nd block interval
block operation is aborted
Pause interval is continued up to end of regular
preset pause time
If a signal is received from the cycle switch during
the 3rd pump running time
block operation
is aborted
Regular preset pause time begins
If the preset PAUSE time tPA is shorter
than 15 min, the block pause blo
corresponds to this value.