9.4.2 Conformance with CE
The drives have been tested by an authorized testing laboratory in a defined configuration,
using the system components that are described in this documentation. Any divergence from
the configuration and installation described in this documentation means that the user will be
responsible for carrying out new measurements to ensure conformance with regulatory
requirements
CE Declarations of Conformity can be found on the Kollmorgen website.
These devices can cause high-frequency interferences in non industrial environments and
may require measures for interference suppression (such as additional external EMC
filters).
Kollmorgen declares the conformity of the product series AKD with the following directives:
EC Directive 2014/35/EC, low voltage
Used harmonized standard EN 61800-5-1:2007
EC Directive 2014/30/EC, electromagnetic compatibility
Used harmonized standard EN 61800-3:2004
AKD-xzzz06 do not have integrated EMC filters.
AKD-xzzz07 have integrated EMC filters.
EC Directive 2006/42/EG, machinery
Used harmonized standards EN ISO 13849-1:2008, EN ISO 13849-2:2012
9.4.3 Safe Torque Off (STO)
The STO safety implementation on the AKD is certified.
The safety circuit implementation for realizing the safety function "Safe Torque Off" in the
drive is suited for SIL2 according to IEC 62061 and PLd, Cat.3 according to ISO 13849-1.
With AKD-x04807 drives SIL3/PLe is possible, if both STO-Enable inputs are used with the
corresponding STO-Status signals.
Safety certificates can be found on the Kollmorgen website.
The subsystems (AKD drives) are totally described for safety technics with the
characteristic data :
Device
AKD-x003...024
AKD-x048
9.4.4 Conformance with EAC
EAC is the abbreviation for Eurasian Conformity. The mark is used in the states of the
Eurasian Customs Union (Russia, Belarus, Kazakhstan) similar to the European CE mark.
Kollmorgen declares, that the AKD has passed all required conformity procedures in a
member state of the Eurasian Customs Union, and that the AKD meets all technical
requirements requested in the member states of the Eurasian Customs Union:
Low voltage (TP TC 020/2011)
Electromagnetic Compatibility (TP TC 004/2011)
Contact: Intelisys LLC. , Bakuninskaya Str. d 14, Building 10, RU-105005 Moskau
Operation
ISO
Mode
13849-1
single channel
PL d, CAT 3
single channel
PL d, CAT 2
dual channel
PL d, CAT 3
dual channel with
PL e, CAT 4
periodical testing
Kollmorgen | kdn.kollmorgen.com | October 2018
AKD Product Safety Guide | 9 Appendix
IEC
PFH
62061
[1/h]
[Years]
SIL 2
1,50E-07
SIL 2
1.88E-07
SIL 2
5.64E-09
SIL 3
5.64E-09
T
SFF
M
[%]
20
100
20
89
20
87
20
87