SPECIFICATIONS RELATING TO THE QUALITY OF THE WATER THAT CAN BE USED WITH THE PUMP
Maximum temperature for UAP models (*)
Maximum temperature for SAP models (*)
Total minimum hardness
Total maximum hardness
pH value
pH
1
Volume of Chlorine (maximum)
Volume of Iron (maximum)
Volume of Manganese (maximum)
Volume of Chloride (maximum)
Volume of Sulphide (maximum)
Dissolved oxygen (minimum)
Harmful abrasive substances dispersed in the water (maximum)
Conductivity
Organic substances (maximum)
All additional values must conform to the DIN 50930 standard.
(*) UAP (Ultra High Pressure) - SAP (Super High Pressure)
CAUTION!
In the case of different values or other chemical substances in the water, please contact the HPP Service
because bad quality water will shorten the life of the sealing components and accessories.
CAUTION!
THE WATER FILTER IS NOT WASHABLE!
2
3
4
5
acidic
7
6
8
9
10
neutral
ppm KMnSO
38
°C - °F
35 - 95
°C - °F
45 - 113
°dH - °f
3 - 5,34
°dH - °f
30 - 53,4
pH
6,5 ~ 8
11
12
13
14
basic
(alkaline)
ppm Cl
ppm Fe
ppm Mn
0,05
ppm Cl
2
ppm SO
4
ppm
ppm
S/cm
< 1000
4
0,5
0,2
100
100
5
5
12