HPP H Serie Instrucciones Para El Ensamblaje -Uso Y Mantenimiento página 46

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
PARTS
PARTS TO CHECK
Oil change (ISO 220)
Check the oil filter
Pump oil
Change the oil filter (*)
Clean the magnetic plug
Bolt M14x30 - 180 Nm
MAP pump
Bolt M24x170 - 320 Nm
Bolt M20x262 - 220 Nm
SAP pumps
I and II
Flange M12x240 - 80 Nm
Bolt M24x240 - 320 Nm
SAP pumps
III and IV
Bolt M24x375 - 320 Nm
Bolt M12x200 - 90 Nm
UAP pump
I
Bolt M20x299 - 220 Nm
Bolt M24x280 - 220 Nm
UAP pump
II
Bolt M24x355 - 450 Nm
Bolt M24x280 - 450 Nm
UAP pumps
Bolt M24x350 - 450 Nm
III and IV
Bolt M16x70 - 150 Nm
Bolt M36x330 - 760 Nm
H500/4
Bolt M24x100 - 576 Nm
pump
Bolt M24x350 - 576 Nm
(*) THE OIL FILTER IS NOT WASHABLE
m
WARNING!
Check correct alignment of the pump-motor coupling
Check tightness of the self-centring joint
Substitute the "gasket kits" to ensure that the equipment works well:
• beforehand every 200 hours on UAP pump models
• beforehand every 500 hours on SAP pump models
• straight after leaks are found on MAP pump models.
The pressure regulator bolts/stud bolts must be replaced every 1000 hours or once a year
The head bolts/stud bolts must be replaced every 10 tightenings
The liner bolts/stud bolts must be replaced every 10 tightenings
Clean the magnetic plug each time the oil is changed – see specifications
PREVENTIVE MAINTENANCE PROGRAMME
46
MAINTENANCE INTERVAL (HOURS)

Publicidad

Tabla de contenido
loading

Tabla de contenido