Display Fault
162
Pressure switch of high pressure pump
was triggered forward for roof nozzles
163
Pressure switch of high pressure pump
was triggered backward for roof nozzles
164
Pressure switch of high pressure pump
was triggered for side nozzles
165
Pressure switch of high pressure pump
was triggered for wheel cleaning
166
Pressure switch of high pressure pump
was triggered for underbody cleaning
167
Pressure switch of high pressure pump
was triggered for floor cleaning
168
Pressure switch of high pressure pump too
high despite bypass switching
172
Anti-frost active (traffic signal forward and
backward blinks five times)
173
CAN bus error module A32 no connection
(additional board water distributor)
174
Excess current outlets CAN bus module
A32 (additional board water distributor)
175
Trailer coupling detected
44
Possible cause
High pressure nozzles of roof blocked
towards the front or compressed air
supply to the portal has stopped or pres-
sure switch is defective
High pressure nozzles of roof blocked
towards the rear or compressed air sup-
ply to the portal has stopped or pressure
switch is defective
High pressure nozzles of side pipes
blokked or compressed air supply to
portal has been switched off or pressure
switch is defective
High pressure nozzles of wheel wash-
ing blocked or compressed air supply to
portal has been switched off or pressure
switch is defective
High pressure nozzles of underbody
cleaning blocked or compressed air
supply to portal has been switched off or
pressure switch is defective
High pressure nozzles of floor cleaning
blocked or compressed air supply to
portal has been switched off or pressure
switch is defective
Compressed air supply to the portal has
been stopped or pressure switch is de-
fective
Frost protection is active
Loose connecting chord of the plates,
plates defective
Short circuit, water leakage
Side brush has got hooked into the trail-
er coupling
19
-
EN
Remedy
Clean the corresponding high pressure
nozzles, check compressed air supply, re-
peat washing process, call Customer Ser-
vice
Check compressed air supply, repeat
washing process, call Customer Service
Washing cannot be done until the anti-frost
temperature is exceeded again
Switch off and switch on the unit, repeat
washing process, call Customer Service
No action is required; washing will continue
automatically without the back being
washed a second time