Water Connections; Water Drain - lamber S200 Manual De Instrucciones

Lavavasos
Ocultar thumbs Ver también para S200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WATER CONNECTIONS

Carefully comply with any national or
regional regulations in force.
Water installation must have the following
characteristics:
Temperature: 10÷12°C
Dynamic Pressure :
2 ÷ 4 bar (200÷400 kPa)
-
WARNING!
If the water pressure is higher than 3 bar, fit
the pressure reducer "A" supplied into the
solenoid valve as shown in the drawing.
If the dynamic pressure is lower than
specified on the data plate of the machine,
it is advisable to install a Booster Pump.
Hardness: between 7,2 and 12,5 °French.
If the hardness values are higher than
those mentioned above, it is advisable to
install a water-softener.
WORK TEMPERATURES
Washing temperature 55°
Rinse temperature 80°
n.b.: To
help
a
correct
thermocontrol system, do NOT adjust the
thermostat during the washing cycle.
DO
NOT
TAMPER
THERMOSTAT CALIBRATION
60°C
÷
85°C
÷
working
of
the
WITH
THE

WATER DRAIN

According to the dimensions of the drawing,
water drain and feeding pipe should have
the same diameter of the water inlet of the
machine.
It must be furnished with a siphon and have
a right slope.
The machine is provided with a flexible pipe
for the connection with the water-work.
Make sure there are no throttlings along the
pipe.
Carefully comply with any national or
regional regulations in force.