Operation; Check The Fill Level Display - Kärcher IVR-L 100/18-2 Tc Dp Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation

Illustration on the inside of the front
cover
 Insert the mains plug into the socket.
Illustration
 Turning on the Appliance
Note: The switch has several switching
stages:
0
Device is switched off
1
Motor 1 switched on
2
Motor 1 and 2 switched on
Always operate the device in stage 2.
ATTENTION
Risk of damage! Always switch the switch-
ing stages quickly in order to prevent dam-
age of the drive motor.
 Start suction process.
Note: When vacuuming up fluids, only im-
merse the accessories half way in order to
deliver sufficient air.

Check the fill level display

Note: The red marking on the drain hose
shows the maximum admissible filling lev-
el.
Draining the fluid container by
means of drum pump
Illustration
 Secure the disposal hose in the support
when it is not used.
Emptying during vacuuming operation
 Connect the disposal hose to the dis-
posal unit.
 Plug in the mains plug of the drum
pump.
 Start vacuuming operation.
 Use the On/Off switch to switch on the
drum pump.
 Adjust the delivery rate by means of the
+/- button.
Note: Choose the delivery rate according
to the vacuumed quantity. Prevent the
drum pump from running dry. Do not leave
the drum pump unattended.
Emptying after the vacuuming
operation
 Switch off the appliance and remove
the plug from the socket.
 Drive the appliance to the disposal site
for the liquid.
 Connect the disposal hose to the dis-
posal unit.
 Plug in the mains plug of the drum
pump.
 Use the On/Off switch to switch on the
drum pump.
 Adjust the delivery rate by means of the
+/- button.
Note: Prevent the drum pump from running
dry. Do not leave the drum pump unattend-
ed.
– 4
EN
9

Publicidad

Tabla de contenido
loading

Tabla de contenido