Vollrath SLM300/S Manual Del Operador página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CLEAN AND SANITIZE THE SLICER
WARNING
Cut and Amputation Hazard
The blade on this commercial slicer is extremely sharp. Severe
injury can occur if care is not used when using or cleaning this
product. Only trained personnel should operate equipment or
perform maintenance. To reduce the risk of injury, the use of a
cut resistant glove(s) is recommended when cleaning this
equipment.
WARNING
Electrical Shock Hazard
Keep water and other liquids from entering the inside of the
equipment. Liquid inside the equipment could cause an
electrical shock. Do not spray water or cleaning products.
Liquid could contact the electrical components and cause a
short circuit or an electrical shock.
NOTICE: This slicer shall be cleaned and sanitized at intervals to
comply with national, state and/or local health codes.
NOTICE: This slicer shall be cleaned and sanitized each time the
blade is sharpened.
Disassemble the Slicer
1. Unplug the slicer from the electrical outlet.
2. Turn the index control knob to the right, past zero (0), until it will not
turn any further. This positions the gauge plate to protect you from
the blade and is required for the carriage tray to be locked.
3. Remove the product grip handle. Note on some models, the handle
is not removable.
4. Turn the carriage release knob until it is very loose. Note: it is not
removable.
Heavy-Duty Electric Slicers Operator's Manual
5. Use the carriage handle to firmly pull (do not force) the carriage tray
forward until you hear a click and it is locked into place.
Note: If it is difficult to lock the carriage tray, verify the index control
knob is turned past zero and as far as possible to the right. Then,
further loosen the carriage release knob.
6. Lift to remove the carriage tray.
7. Grasp the knob on the blade cover with one hand. With the other
hand, loosen and push the blade cover knob to lift the blade cover
from the blade.
8. Lift the blade sharpening assembly and rotate it 90° counter-
clockwise. Lift to remove it.
9. Remove the slice guard.
10.Use a clean cloth to remove all coarse residual food and liquid from
the slicer surfaces.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

40952

Tabla de contenido