Ravaglioli RAV307H.4WS-VARSC Manual De Instrucciones página 141

Tabla de contenido

Publicidad

8
8.1.12 ERROR 22 HOOK RELAY FAIL
The column signals this problem when pilot problems are detected on relay K6 of the electronic board.
In this case, try to switch off and back on all the columns, select LAST CONFIG.
If the problem persists, you need to contact the technical service.
8.1.13 ERROR 13 WRONG MACADDRESS
The column signals this type of error when the configuration is no longer valid. In this case, you need to bring all the columns to
the ground, switch them off and execute a new configuration.
8.1.14 ERROR 16 OSCILLATOR FAIL
The column signals this type of error when a malfunction occurs inside.
In this case, try to switch off and back on all the columns, select LAST CONFIG.
If the problem persists, you need to contact the technical service.
8.1.15 ERROR 17 HOPE-FRAME FAIL
The column signals this type of error when a malfunction is detected on the module managing communication between the columns.
In this case, try to switch off and switch back on all the columns, select LAST CONFIG.
If the problem persists, you need to contact the technical service.
8.1.16 ERROR 24 Internal Regs KO
8.1.17 ERROR 25 StackPointer KO
8.1.18 ERROR 26 FlashCheckSum KO
The column signals this type of error when a malfunction occurs inside.
In this case, try to switch off and back on the column. If the problem persists, you need to contact the technical service.
8.1.19 ERROR REDUNDANCY FAIL
If the column signals the following error codes, it means the electronic board has detected a problem inside relating to communi-
cation between the two micro-controllers
present. Try to switch off and switch back on the columns on the lift and select LAST CONFIG.
If the problem persists, you need to contact the technical service.
Possible errors list:
ERROR 50
ERROR 65
ERROR 68
ERROR 82 → 86
ERROR 100 → 105
ERROR 243
8.1.20. ERROR 29 PAR-VAL PSW LOAD DEFAULT
The column signals this type of error when an error is detected on loading the functioning parameters.
In this case, try to switch off and back on the column, if
the problem persists you need to ask Technical Support for instructions.
8.1.21. ERROR 30 PAR-REL LOAD DEFAULT ?
The column signals this type of error when an error is detected on loading the functioning parameters.
In this case, try to switch off and back on the column, if the problem persists you need to ask Technical Support for instructions.
141