Exterior Covers and DeVilbiss Rechargeable Battery
To avoid electric shock, do not remove the iGo covers� The covers should only be removed by a qualified DeVilbiss provider�
Do not apply liquid directly to the covers or utilize any petroleum-based solvents or cleaning agents�
Use of harsh chemicals (including alcohol) is not recommended� If bactericidal cleaning is required, a non-alcohol based
product should be used to avoid inadvertent damage�
The exterior covers and rechargeable battery should be cleaned as needed. To clean, follow these steps:
1.
Turn the iGo Off and disconnect from AC or DC power before cleaning.
2.
The battery should remain installed and be wiped clean with the covers. If battery is removed, wipe the battery bay and battery with a Dry
Cloth only.
3.
Clean the iGo exterior covers by using a damp cloth with a mild household cleaner and wipe it dry.
Humidifier (reusable bottle)
If your physician has prescribed humidification for use during continuous flow mode, clean your humidifier bottle daily. Follow the instructions
supplied by the manufacturer. If no cleaning instructions were supplied, follow these steps:
1.
Wash the humidifier in a solution of hot water and dishwashing detergent.
2.
Soak the humidifier in a solution of one part white vinegar to three parts hot water for 30 minutes. This solution acts as a germicidal agent.
3.
Rinse thoroughly with hot tap water and refill with distilled water for use. Do not overfill.
Rolling Carry Case and Detachable Wheeled Cart
The carry case and/or cart should be cleaned as needed. To clean, follow these steps:
1.
Remove the iGo from the carry case or cart before cleaning.
2.
Clean the case or cart by using a damp cloth with a mild household cleaner and wipe dry.

Battery Storage

Your Battery should be stored in a cool, dry location when not in use.

Battery Disposal

Your Battery is rechargeable and can be recycled. Contact your DeVilbiss provider before disposal of battery or any iGo components.
Disposal of Equipment and Accessories
Follow local governing ordinances and recycling plans regarding disposal of device components. Do not dispose of the rechargeable Battery.
Contact your DeVilbiss provider before disposal of battery or any iGo components.

sPeCIfICaTIons

Dimensions (H x W x D) ....................................................................................19.3 inches x 12.3 inches x 7.1 inches (49.0 cm x 31.2 cm x 18.0 cm)
Weight .............................................................................................................................................................................19 pounds (8.6 kg) with Battery
Flow Rate Settings .................................................................................................................................................................... 1 to 6 in PulseDose Mode
Maximum Recommended Continuous Flow (@ nominal outlet pressures of 0 and 7 kPa) .................................................................................. 3 LPM
Maximum Breathing Rate (PulseDose mode only) ...................................................................................................................... 40 BPM @ settings 1-4
Oxygen Concentration ................................................................................................................................................... 91% ± 3% for all flow settings
Maximum System Pressure ................................................................................................................................................................. 15 psig (103.5 kPa)
Oxygen Outlet Pressure .................................................................................................................................................... 5.0 ± 1.0 psig (34.5 ± 7 kPa)
Operating Temperature........................................................................................................................................................ 41°F to 104°F (5°C to 40°C)
Operating Humidity ........................................................................................................................................... 10% - 95% at 82.4°F (28°C) dew point
Transportation and Storage Temperature ................................................................................................................. -4°F to +140°F (-20°C to +60°C)
Transportation and Storage Humidity .................................................................................................................................... up to 95% non-condensing
14
A-306
� WArning
specificAtions
15.5 pounds (7.0 kg) without Battery
1 to 3 LPM in Continuous Flow Mode
37 BPM @ setting 5
31 BPM @ setting 6