Nice Neomat T Instrucciones Y Advertencias Para La Instalación Y El Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
Follow the procedure shown in table A4 to memorise the intermediate position:
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Table "A4" - Programming of the intermediate position "I"
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
01. Using buttons ▲ ■ ▼ of a remote control, move the
awning into the "I" position to be memorised.
02. Press and hold down button ■ until you hear a beep
5s...
(after about 5 seconds).
03. Release and press again button ■ for another 5 seconds
5s...
until 4 rapid beeps are heard.
04. Press buttons ▼ and ▲ together until 3 beeps are
heard, indicating that the position has been memorised.
4.3.2 - Deactivation or reactivation of Torque Reduction on closing (RDC)
Torque reduction is a function that reduces the traction torque before complete closure
of the awning against the casing, to avoid excessive tensioning of the fabric. This function
is activated automatically after programming positions 0 and 1 (programming is always at
maximum force) but can be deactivated (or re-activated) if required.
Note - automatic activation of the RDC function does not occur if position programming is
performed using programmers TTP, TTI and O-ViewTT; in these cases the function can be
activated manually as required.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Table "A5" - Deactivation or reactivation of Torque Reduction (RDC)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
01. Press and hold down button ■ of a previously memorized
5s...
transmitter until you hear a beep (after about 5 seconds).
02. Release and press again button ■ for another 5 seconds
5s...
until 4 rapid beeps are heard.
03. Press ■ until the signal beeps are emitted: 3 Beeps indi-
(...)
cate RDC active (closure at reduced torque); 5 Beeps
indicate RDC not active (closure at maximum torque).
4.3.3 - RDC level programming through the remote control
The procedure allows the setting of the impact force which the motor will apply in the box
closure phase (4 adjustable thresholds).
Level 1 → TTP LED solid on
Level 2 →
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Table "A6" - RDC level programming through the remote control
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
01. Press keys ▲ and ■ of the TLC saved in "Mode I" at the
same time until the motor makes 1 beep.
x 1 = Level 1
02. Within 5 seconds, press with intervals of 2 seconds the
x 2 = Level 2
key ▲ of the TLC to select the desired level (press once =
x 3 = Level 3
level 1; press twice = level 2......press 4 times = level 4).
x 4 = Level 4
03. Wait for the motor to confi rm the level just selected with a
x 1 = Level 1
number beeps (E.g.: 3 beeps = level 3 selected).
x 2 = Level 2
x 3 = Level 3
04. Within 5 seconds from the last beep, confi rm the level by
x 4 = Level 4
briefl y pressing the ■ key.
05. If the procedure has been carried out correctly the motor
will make 3 beeps.
4.3.4 - Deleting positions
To modify the previously memorised positions, they must firstly be cancelled and then the
new positions programmed again.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Table "A7" - Cancellation of the intermediate position "I"
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
01. Press and hold down button ■ of a previously memorized
5s...
transmitter until you hear a beep (after about 5 seconds).
02. Release and press again button ■ for another 5 seconds
5s...
until 4 rapid beeps are heard.
03. Press buttons ▼ and ▲ together until 5 beeps are heard,
in di cating that the intermediate position has been cancelled.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Table "A8" - Cancellation of positions "0" and "1"
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
01. Press and hold down button ■ of a previously memorized
5s...
transmitter until you hear a beep (after about 5 seconds).
02. Release and press again button ■ for another 5 seconds
5s...
until 4 rapid beeps are heard.
03. Press button ▼ until 5 beeps signal that positions "0"
and "1" have been cancelled.
WARNING: After deleting positions "0" and "1" the awning moves in hold-to-run mode
and the new positions need to be memorised.
Note: the intermediate positions "I" and the RDC function that are programmed are not cancelled.
If you wish to cancel everything (including the codes of the transmitters), refer to table "A15".
4.3.5 - Climate management
Response to sun:
– At the sun overthreshold command by a climate sensor, the motor will carry out the
opening of the awning.
English – 5

Publicidad

Tabla de contenido
loading

Tabla de contenido