Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.3

taBle

During firsttime calibration, the calibration plates are in the
spherical shells. For calibration after a milling process, the
calibration plates must be inserted for calibration. Control the
diameter of the tool shank of a scanner (e. g. T3/T4) in the
bores on the scanner side of the calibration plates (must be
able to move easily, otherwise select another scanner).
Insert scanner on scanning side inversely.
Upgrade kit
Multi-x
O P e r at I n g I n s t r U C t I O n s
Pull out the scanner from the clamp about 2 mm and close
the clamp again.
The spherical shell table must now be aligned vertically with
the tool (baseline position). Place the calibration aid between
the two spherical shells, keep the foot switch pressed down
and press on the calibration aid. Then release foot switch and
remove the calibration aid.
CaUtIOn! If the counterweights are not installed, hold tight
the spherical shells before releasing vacuum.
The spherical shells are now roughly adjusted to the baseline
position so the inverted scanner can be introduced partly
(usually completely) into the hole.
gB
37

Publicidad

Tabla de contenido
loading

Tabla de contenido