5.2 On−the−spot diagnosis via the 7−segment display
The 7−segment display shows the operating statuses
during running up and operation. In case of error, fault
codes are shown on the 7−segment display. Possible
error codes are dependent on the current operating status
of the device and summarised accordingly in the following
tables. This means that a first diagnosis is possible with
out reading out the status report files.
Error displays not listed are intended for the support team
at Festo.
Error during Power−on self−test:
Error
Cause
2−E401
Extended boot system was
not found
2−E402
CRC error in extended boot
system
2−E403
Boot system not suited for
HW revision
28
Action
Re−initialise the memory card
with FCT
Re−initialise the memory card
with FCT
Re−initialise the memory card
with FCT
Festo GDSP−CMXR−SY−ML 0805NH English