With the brushes base group in
lifted position, insert the brushes
into their plate seat underneath
the brushes base turning them
until the three metal buttons are
properly seated in their slots;
quickly rotate the brushes to
push the button towards the
coupling spring until they get
blocked.
The figure shows the rotating
sense for brushes coupling.
For a longer life of the brushes
we suggest to invert daily their
position. Whenever brushes are
deformed we suggest to reas-
semble them in the same posi-
tion, avoiding that the different
inclination of the bristles causes
excessive motor overload or
troublesome vibrations.
ATTENTION:
Use only brushes supplied with
the machine or the ones indicat-
ed in the paragraph "RECOM-
MENDED BRUSHES". The use
of other brushes can compro-
mise security.

FLOOR CLEANING

CONNECTION OF THE BAT-
TERIES TO THE MACHINE
Once that the battery recharging
has been completed:
1. Disconnect the connector
(3) of the battery recharger (1).
To do this, it is necessary to
reach the battery compartment
as indicated under paragraph
"ACCESS TO THE BATTERY
COMPARTMENT".
2. Connect instead the machine
connector (2).
3. Close the battery compart-
ment.

RECOVERY TANK

Check that the cover of the
suction filter (1) is correctly se-
cured, after rotating the levers
(2) and that the suction motor
hose (3) is correctly connected
to it.
Verify also that the squeegee
hose couplings (4) are correctly
inserted into the seats, that the
exhaust hose plug (5) placed in
the front part of the machine is
closed and the inspection cap
(6) is closed well.
14
DETERGENT SOLUTION
TANK
The capacity of the detergent
solution tank is indicated in the
technical data.
Open the screw plug placed
in the rear left part of the ma-
chine and fill the solution tank
with clean water at a maximum
temperature of 122°F (50°C).
Add the liquid detergent in the
percentage and conditions fore-
seen by the manufacturer. To
avoid excessive foam presence,
which could cause problems to
the suction motor, use the mini-
mum percentage of detergent.
Screw down the plug to close
the tank.
ATTENTION:
Always use low foam detergent.
To avoid foam presence, be-
fore starting working operation,
introduce into the recovery tank
a minimum quantity of anti-foam
product.
Never use pure acid.