BEFORE USE
HANDLING OF THE PACKED
MACHINE
The machine is supplied with
suitable packing fore-seen for
fork lift truck handling.
The total weight is 562 lbs.
(255kg)
Packing dimensions:
Base: 70" (178 cm) x 37" (93
cm)
Height: 54" (138 cm)
ATTENTION:
Do not place more than 2 pack-
ings on top of each other.
UNPACKING OF THE MA-
CHINE
1. Remove the external packing.
2. Unscrew the brackets (1+2)
that secure the machine to the
pallet.
3. Move the machine back-
wards, avoiding heavy contacts
to mechanical parts.
4. Keep the pallet and the
brackets for eventual transport.
ACCESS TO THE BATTERY
COMPARTMENT
In order to reach the battery
compartment, it is necessary
to rotate forwards the recovery
tank (1).
Before rotating it, it is necessary
to:
1. Bring the machine on a lev-
elled surface.
2. Take off the squeegee hose
(2) from its seat.
3. Take off the suction cover (4)
after turning the blocking levers
(3).
4. Verify by lifting the filter and
its protection, that the tank is
empty, otherwise, proceed to
the empty as indicated under
paragraph "RECOVERY TANK
CLEANING"
5. Rotate the tank from its rear
handle until the gas shock ab-
sorber (1) acts, which lifts it up
to a first position. Lifting it more,
the maximum opening can be
obtained.
6. Having finished any type of
intervention, close the battery
compartment pushing the tank
downwards if it is open at the
first position, while from the
maximum opening it is neces-
sary to unblock the support of
the gas shock absorber (1).
7. Reassemble everything
10
BATTERY INSTALLATION AND
SETTING OF THE BATTERY
TYPE
The machine is equipped either
with batteries in serial connec-
tion or elements of DIN-type
assembled together and con-
nected in series, placed in its
appropriate compartment under
the recovery tank and must
be handled using suitable lift-
ing equipment (due to weight,
considering the type of batteries
chosen, and coupling system).
The batteries must be in accor-
dance with CEI 21-5 Norms.
The machines at 24V will fit the
batteries into the appropriate
reduced steel basin.
ATTENTION:
The machine and its battery
check card foresee the use of
traditional lead batteries.
CHECK SETTING OF THE
CHECK CARD ON THE INDI-
CATOR (1) (see under para-
graph "BATTERIES CHARGE
LEVEL INDICATOR").
In case of GEL batteries instal-
lation, it is necessary to set
the battery check card. Please
contact the authorized technical
assistance.
ATTENTION:
Strictly follow manufacturer/
distributor indications for the
maintenance and recharge of
the batteries.