Lenze TML Instrucciones Para El Servicio página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Commissioning
Code
No.
Name
C18
Chopper frequency
Slip compensation
C21
Current limit
C22
C24
Accel boost
C34
Configuration -
analog input
C36
Voltage - DC injection
brake (DCB)
C37
Fixed setpoint 1
(JOG 1)
C38
Fixed setpoint 2
(JOG 2)
Fixed setpoint 3
C39
(JOG 3)
Frequency setpoint
C46
Torque setpoint/range
C47
C50
Output frequency
C52
Motor voltage
C53
DC bus voltage
C54
Motor current
C56
Controller load
Motor torque
C57
C65
Vector speed control
loop gain
C66
Vector speed stability
16
Possible Settings
Lenze Selection
2
0
4 kHz
1
6 kHz
2
8 kHz
3
10 kHz
0.0
0.0
{%}
C21 not active in Vector mode (see C14)
200
30
{%}
Reference: Tml rated output current
0.0
0.0
{%}
0
0
0...10 V
1
0...5 V
2
Reserved
3
0...20 mA
4
4...20 mA
5
4...20 mA monitored
4.0
0.0
{%}
20.0
0.0
{Hz}
30.0
0.0
{Hz}
40.0
0.0
{Hz}
0.0
{Hz}
100
0
{%}
0.0
{Hz}
0
{V}
0
{V}
0.0
{A}
0
{%}
0
{%}
30.0
0.0
30.0
0.0
Lenze 13466187 EDBTL03 v8 EN, DE, FR, IT, ES
IMPORTANT
• As chopper frequency is increased,
motor noise is decreased
• Observe derating in Section 2.2
• C18 = 1, 2, 3: Automatic derating to
4 kHz at 1.2 x I
N
40.0
Change C21 until the motor speed no
longer changes between no load and
maximum load
200
• When the limit value is reached,
either the acceleration time
increases or the output frequency
decreases
• When c73 = 0, max setting is 167%
20.0
Accel boost is only active during
acceleration
• With 250 Ω resistance between
terminals 7 and 8
• C34 = 5 will trigger 5d5 fault if
signal falls below 2 mA
50.0
• See CE1...CE3 and c06
• Confirm motor suitability for use
with DC braking
240
Lenze setting: active at E1 = HIGH
240
Lenze setting: active at E2 = HIGH
240
Lenze setting: active at E1 = HIGH
and E2 = HIGH
240
Display: Setpoint via analog input,
function UP/DOWN
400
• When C14 = 5 and C01 = 1, 3, 5, 7
sets the torque setpoint
• When C14 = 5 and C01 = 0, 2, 4, 6
sets the torque range for C34
240
Display
999
Display
999
Display
400
Display
255
Display
400
Display: vector mode only
(C14 = 4, 5)
100
Optimizes dynamic performance in
vector mode
100
Optimizes steady-state speed stability
in vector mode

Publicidad

Tabla de contenido
loading

Tabla de contenido