Parameter setting and display

To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
<
and
o
same time until "tS" (installer) appears on the 2 digits of the
display which alternate with "0.1" (parameter number) and a
(set value)
"2"
– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
holding the buttons
>
NOTE:
scrolling movement.
3.4

List of parameters

Type
No.
Description
tS
0.1
Index showing boiler power in kW
tS
0.2
Hydraulic configuration
tS
0.3
Gas Type Configuration
tS
0.4
Combustion configuration
tS
0.8
External sensor value correction
tS
0.9
Ignition fan speed
tS
1.0
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
tS
1.1
-- = Disabled
tS
1.2
Heating Curve Incline
tS
1.3
Minimum Heating Temperature Adjustment
tS
1.4
Maximum Heating Temperature Adjustment
tS
1.5
Maximum power heating
tS
1.6
Heating Post-Circulation Time
tS
1.7
Heating Pump Activation Delay
tS
1.8
Heating Re-ignition Delay
tS
1.9
Domestic Hot Water Modulation with Flow meter
tS
2.0
Maximum power domestic hot water
(approximately 5 seconds) at the
or
<
increases the speed of the
CONFIGURATION
DOMESTIC HOT WATER - HEATING
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
<
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
o
at the same time
initial screen is displayed.
Range
0 = 24 kW
1 = 25 kW
2 = 30 kW
3 = 35 kW
4 = 40 kW
0 = rapid
1 = storage tank with thermostat or heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
5 = open vent
6 = boiler with heat pump
0 = G20
1 = G31
2 = G230
0 = sealed chamber with combustion control
1 = open chamber with smoke thermostat
2 = Low Nox
-5 .. +5
80 .. 160
0 .. +10
-9 .. +5
0 .. 80
20 .. Par tS 1.4
Par tS 1.3 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 = Disabled
1 = Enabled
0 .. 100
to decrease it
for approximately 5 seconds until the
U/M
Step
-
1
-
1
-
1
-
1
°C
1
RPMx25
1
°C
1
°C
1
-
1
°C
1
°C
1
%
1
seconds
1
x 10
seconds
1
x 10
Min
1
-
1
%
1
<
Default
0 or 1
or 2 or
3 or 4
0
0
0
0
128
3
-2
20
20
80
100
3
0
3
1
100
83