3.3

Parameter setting and display

To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
<
and
same time until "tS" (installer) appears on the 2 digits of the
display which alternate with "0.1" (parameter number) and a
(set value)
"2"
– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
holding the buttons
NOTE:
scrolling movement.
3.4

List of parameters

Type
No.
Description
Index showing boiler power in kW
tS
0.1
0 = 24
tS
0.2
Hydraulic configuration
tS
0.3
Gas Type Configuration
tS
0.4
Combustion configuration
tS
0.8
External sensor value correction
tS
1.0
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
tS
1.1
-- = Disabled
tS
1.2
Heating Curve Incline
tS
1.3
Minimum Heating Temperature Adjustment
tS
1.4
Maximum Heating Temperature Adjustment
tS
1.5
Maximum power heating
tS
1.6
Heating Post-Circulation Time
tS
1.7
Heating Pump Activation Delay
tS
1.8
Re-ignition Delay
80
o
(approximately 5 seconds) at the
>
or
<
increases the speed of the
DOMESTIC HOT WATER - HEATING
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
o
at the same time
initial screen is displayed.
Range
CONFIGURATION
-
0 = rapid
1 = storage tank with thermostat or
heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
0 = G20
1 = G31
0 = sealed chamber with combustion
control
1 = open chamber with smoke thermostat
2 = low NOx
-5 .. +5
0 .. +10
-9 .. +5
0 .. 80
20 .. Par tS 1.4
Par tS 1.3 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
<
to decrease it
for approximately 5 seconds until the
U/M
Step
-
-
-
1
-
1
-
1
°C
1
°C
1
°C
1
-
1
°C
1
°C
1
%
1
seconds
1
x 10
seconds
1
x 10
Min
1
EN
<
Default
0
0
0 or 1
1
0
3
-2
20
20
80
100
3
0
3