– Heating programme
– D.H.W. programme
With the heating programme it is possible to set the switching times of the temperature for a
period of a week. The weekly programme consists of 7 daily programmes. One daily program-
me allows 3 phases of heating. Each phase is defined by a ignition time and a finishing time. The
n° 8 daily programme is for the domestic hotwater service. If a phase is not required, the same
ignition and finishing time may be entered.
Select the days that correspond with the heating phase.
4
1= Monday, ... 7 = Sunday/8 = hot-water service programme
5
Start of phase 1: heating with fixed modality
6
End phase 1: heating with reduced modality
7
Start phase 2: heating with fixed modality
8
End phase 2: heating with reduced modality
9
Start phase 3: heating with fixed modality
10
End phase 3: heating with reduced modality
1 1
Copying of the daily programme
By pressing this key it is possible to repeat the current heating programme
for the next day.
By pressing this key it is possible to repeat the current heating programme
for the previous day.
As a confirmation the following day is displayed.
With the Logica Remote Control it is possible to manage the temperature of D.H.W. tank on
two levels (a comfort level and one at reduced temperature) in accordance with the program-
me chosen with parameter 62 (load domestic hot water). To have access to the parameter
press the
and
keys for at least 5 seconds and then go along the entered lines with the
key until parameter 62 is reached. At this point four different programmes may be selec-
ted with
o
keys, with the following characteristics:
0 = 24 hours/ day - Hot water is always available at the temperature set with user parame-
ter n°3.
1 = standard - Hot water according to the daily heating programme.
In the comfort areas of heating the temperature of the D.H.W. tank is regulated to the
value set with user parameter n° 3.
In the reduced areas of heating the temperature of the D.H.W. tank is regulated to the
value set with parameter n° 61 of the service level.
2 = service disconnected
3 = second daily programme (8) - Every day of the week the temperature of the hot water is set
according to programme 8. In this case there is a single programming for all the days of the
week and three time zones are available. In the time spans set the temperature of the D.H.W.
tank is regulated according to that set in parameter n°3. In the remaining hours the D.H.W.
tank is controlled to the temperature set with parameter n° 61 the of service level.
5
Start phase 1: preparation of the D.H.W. tank to the comfort temperature
6
End phase 1: Temperature of D.H.W. tank maintained at the reduced value
7
Start phase 2: Preparation of D.H.W. tank to the comfort temperature
8
End phase 2: Temperature of D.H.W. tank maintained at the reduced value
9
Start phase 3: preparation of D.H.W. tank to the comfort temperature
10
End phase 3: Temperature of D.H.W. tank maintained at the reduced value
109