– In case of the break down and/or improper functioning of the apparatus, deactivate it, refraining from any attempts
to repair it or directly intervene. Call exclusively the authorised technical staff.
– The installation of the boiler and any other assistance or maintenance must be carried out by qualified personnel. It is
absolutely prohibited to tamper with the sealed devices.
– It is absolutely prohibited to obstruct the airflow grilles and the aeration opening of the room where the apparatus is
installed.

LIGHTING AND OPERATION

BOILER IGNITION (fig. 1)
Open the gas cock, lower the cover of the
control and activate the boiler by turning
the selector knob to the summer (
position.
When the green led (
city is present in the boiler.
OPEN
APRE
104
USER INSTRUCTIONS
– With the selector knob on the summer
(
the temperature of the hot water to the
fixed value.
).
– With the selector knob on the winter
position (
) lights up, electri-
ched the temperature set on the heating
potentiometer, will begin to modulate auto-
R
R E M O T E
C O N T R O L
GREEN LED
SPIA VERDE
ATTENTION
) position, the boiler works to take
) the boiler, once it has rea-
Fig. 1
matically in order to supply the system with
the effective power requested.
The boiler will stop functioning if the room
stat or "Logica Remote Control" intercede.
TEMPERATURES
ADJUSTMENT (fig. 2)
The panel of the red leds is graduated from
40÷80 °C and shows the temperature in
the D.H.W. tank when the two service leds
(
) are off; it shows the temperature
of the primary circuit when one of the two
leds is lit up.
– Regulation of the D.H.W. temperature is
carried out by acting on the hot-water
service knob (
). The set temperature
is displayed on the scale of the red leds
from 40 ÷80 °C.
– Regulation of the C.H. temperature is
carried out by acting on the heating knob
(
). The set temperature is shown on
the scale of the red leds from 40÷80 °C.
To guarantee an always optimal output
from the generator it is advised not to
go below a minimum operating tempera-
ture of 50 °C.
TURNING OFF BOILER (fig. 1)
To turn the boiler off place the selector
knob on the OFF position.
IF THE BOILER IS NOT GOING TO BE USED
FOR A LENGTHY PERIOD IT IS ADVISED TO
TURN OFF THE ELECTRICITY SUPPLY,
CLOSE THE GAS COCK, AND IF LOW TEM-
PERATURES ARE FORESEEN, EMPTY THE
BOILER AND THE HYDRAULIC SYSTEM TO
AVOID BREAKAGE IN THE TUBES DUE TO
THE FREEZING OF THE WATER.