- When the soldering flux turns liquid the extractor
will automatically lift the component.
There are different models of protectors and
extractors as accessories.
The measurements of all the extractors and
protectors are given on page 47 of instructions
manual.
C) Tripod:
For small components for which an extractor
cannot be used, we recommend use of tripod 20
Ref. 0932050, as shown in the figure.
Use the tripod 40 Ref. 0932250 for larger integrated
circuits.
MAINTENANCE
Exchanging the heater.
Use a wrench to unscrew the cover.
Move back the spring and the cover. Pull the
connector from the socket to disconnect the heater
from the station.
O-ring ø17 x ø1,8
Follow this process inverted to re-connect the heater.