OPERATING INCIDENTS
The suction cup does not adhere to the
component.
Deficient aspiration, Vacuum.
1 Verify if the suction cup is well placed and in
perfect condition.
2 Check the incoming air filter in the interior of
the station and replace it if dirty or obstructed.
Filter
Ref. 0861800
Error messages
Whenever the ERR message appears, the
equipment turns itself off completely.
The following messages are displayed:
- BLANK SCREEN
Power failure.
Check for blown fuses.
- ERR 3
No reading from the thermocouple.
Possible cause: open thermocouple.
- ERR 6
Insufficient air flow which causes an excesive
rise of the heating temperature.
Before recuperating this type of error you must
wait until the temperature goes down.
Possible causes: leaking or blocked air conducts
or faulty self-contained air pump.
- ERR 8
Faulty reading of the rotationsmeter of the airpump.
Possible causes: air pump damaged or faulty
function of the optical sensor circuit.
To recuperate any of these errors actuate the
general switch at the back of the station, the
pedal should not be pushed at this moment.
Temperature sealing-cover
Accessory which replaces the
selection temperature button
and it is use to prevent
operators from changing the
temperature that has been pre-
selected.
Indicates
selected temperature.
JBC reserves the right to make technical changes without
prior notification.