Descargar Imprimir esta página

Balluff BML-S1H1 Serie Guia De Inicio Rapido página 7

Sistema de medición de desplazamiento incremental de codificación magnética

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
BML-S1H1/2-B/S6 _ C-M3_ _ -D0-KA _ _ , _ -S284
Absolute Magnetic Linear Encoder
Installation and connection (continued)
NOTICE
Interference in function
Improper assembly of the magnetic tape and sensor
head may impair function of the linear encoder and lead
to increased wear or damage to the system.
► All permissible distance and angle tolerances must
be strictly complied with.
► The sensor head may not come into contact with
the magnetic tape over the entire measuring range.
Contact must also be avoided if the magnetic tape is
covered by a cover strip (optional).
► The linear encoder must be installed in accordance
with the indicated degree of protection.
Pin
Signal
1
WH
+B (+Cos)
2
BN
−B (−Cos)
3
GN
+Clk
4
YE
−Clk
5
GY
−Data
6
PK
+Data
7
BU
GND
8
RD
U
B
9
BK
−A (−Sin)
10
VT
+A (+Sin)
11
GY PK
GND sense GND sense
12
RD BU
U
sense
B
PH
Shield
PE
12-wire cable with sense lines (measuring lines) to avoid
voltage drops in the supply.
11 3
2
10
4
1
5
9
12
6
8
7
M12 plug pin assignment (view on pin side)
Shielding and cable routing
Defined ground!
The linear encoder and the control cabinet must
be at the same ground potential.
www.balluff.com
Requirement
Cosine-shaped voltage
signal
Cosine-shaped voltage
signal, inverted
Clock signal
Clock signal
Data signal
Data signal
Sensor ground (0 V)
Supply voltage +5 V DC
Sine-shaped voltage signal,
inverted
Sine-shaped voltage signal
U
sense
B
Connector housing/shield
Shielding and cable routing (continued)
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
The cable shield must be grounded on the controller
side, i.e. connected to the protective earth conductor.
When ducting the cable between the sensor, controller,
and power supply, it is important to avoid going near
high voltage cables due to interferences. Stray noise
from AC harmonics (e.g. from phase angle controls or
frequency converters) are especially critical and the
cable shield offers very little protection against this.
Magnetic fields
The linear encoder is a magnetic system. It is important to
maintain adequate distance between the linear encoder
and strong, external magnetic fields.
Cable routing
Do not route the cable between the linear encoder,
controller, and power supply near high voltage cables
(inductive stray noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least
7.5 times the cable diameter.
Cable length
Max. cable length 20 m. Longer cables may be used if
their construction, shielding and routing prevent noise
interference.
Startup
DANgER
Uncontrolled system movement
When starting up, if the linear encoder is part of a closed
loop system whose parameters have not yet been set,
the system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections or devices.
2. Turn on the system.
3. Check measured values in the controller and reset if
necessary.
The BML is an absolute measuring system.
When the supply voltage is switched on, the
absolute position is immediately available
without the need for a reference run. The sensor
head may not be removed from and replaced
on the magnetic tape during operation.
english
3

Publicidad

loading

Este manual también es adecuado para:

Bml-s1h2 serie