17. Limitations to operation, BM hp circulation
pump
The flow limits stated in the table below apply to the optimum
operating ranges of the pumps as regards efficiency and cooling:
Recommended flow rates at 25 °C (77 °F)
3
m
Type of BM hp
50 Hz
BM 5A
3.2 - 5.6
BM 8A
5 - 9.5
BM 17
8 - 24
BM 30
15 - 38

17.1 Cooling

The temperature and flow limits stated in the table below must be
observed to ensure sufficient cooling of the motor:
Maximum permissible liquid temperature
Maximum
liquid
Motor
temperature
°C
°F
Grundfos
40
104
MS 6"
/h
US GPM
60 Hz
50 Hz
60 Hz
3.3 - 6.4
14 - 25
14 - 28
7 - 9
22 - 48
30 - 40
8 - 29
35 - 106
35 - 128
18 - 45
66 - 167
79 - 198
Minimum
flow velocity
Minimum flow
past the
motor
3
m/s (ft/s)
m
/h (US GPM)
≥ 0.15 (0.49)
≥ 5.5 (24)