Electrical Connections - DITEC OLLY M Manual Para La Instalacion Y La Manutencion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
4.

ELECTRICAL CONNECTIONS

GB
Radar RER
Alimentazione / Power supply
230 V~ / 0,3 A
4.1 Controls
Control
1
3
1
4
1
3
1
4
41
4.2 Outputs and accessories
Output
1
0
1
BL
RER
4.3 Trimmer
TC
MAX=disabled
0 s
4.4 Signalizations
LED (bicolor)
Green
Red
4.5 Dip-Switches
DIP1
Closure thrust. Maintain the door in the closure position.
DIP2
Direction selection. The opening direction is intended by
viewing the automation from the side being examined.
OLLY M - IP1894
OPENING
N.O.
CLOSING
N.O.
STOP
N.O.
SAFETY REVERSAL
N.C.
8
+
-
+
-
Automatic closure time. From 0 to 30 s. Adjust the time that passes between the end
of the opening manoeuvre and the start of the automatic closing manoeuvre. The count
30 s
is reset when an opening command is given with the door open. Adjust the TC to the
minimum if automatic closure is not required.
24 V= power supply.
Safety 41-8 open.
Description
0 1 3 4 8 41BL
RER
TC
Function
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
The coincidence of an opening and closing command
stops all movements.
Warning: when the contact closes again the door proceeds
with the interrupted manoeuvre.
The opening of the contact during the closure manoeuvre
causes the movement to invert (opening).
Value
Accessories power supply. External accessories power
24 V= / 0,3 A
supply output.
DO NOT USE
RER radar. Permits the connection of one or two RER radars.
Warning: set the RER radar dip/switch =DX.
Light
Disabled.
Lefthand opening.
12
-
+ Uscita / Output 24 V= / 0,3 A
Apertura / Opening
Chiusura / Closing
Riapertura / Re-opening
Elettroblocco / Electric lock
LED
ON
1 2
Description
Description
Blinking
Encoder / automation fault.
Safety test failure.
OFF
Enabled.
Righthand opening.
ON

Publicidad

Tabla de contenido
loading

Tabla de contenido