5. ELECTRICAL CONNECTIONS
Alimentazione
Power supply
230 V~ 0,2 A
i
-Max section of the wire that can be used on a single clamp = 1.3 mm ² (26AWG).
-If used wires with a larger diameter or more wires, make an external connection using a special terminal (not supplied).
5.1 Commands
Command
Funzione
1
3 N.O. OPENING
1
4 N.O. CLOSING
1
3
N.O. STOP
1
4
1
6 N.C. NOT USED
CLOSING
1
8 N.C.
SAFETY
CONTACT
SAFETY
41
(+)
N.C.
DEVICES
0
(-)
TEST
5.2 Output and accessories
Output
Value - Accessories
0 1
- +
EN
ON
BL
41
8
6
4
3
1
ON
TC
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
The coincidence of an opening and closing command stops all movements.
WARNING: when the contact opens again the door proceeds with the
interrupted manoeuvre.
Make a jumper on contact 1-6 if DIP 3 =OFF, make a jumper on contact 41-6 if DIP 3 =ON.
The opening of the contact reverses the movement (re-opening) during the closing operation.
NB: If no closing safety device is used and DIP3= ON, a jumper must be made on contacts 41-8.
Terminal 41 activates a test of the safety device on each cycle. If the test fails the RED LED flashes briefly and
the test is repeated. With DIP3=ON connect terminal 41 and 0 of the control panel to the corresponding test
terminals on the safety device.
If the safety devices are not tested, see description DIP3=OFF.
Accessories power supply.
Power supply output for external accessories.
24V
0,36A
Safety devices test
0
BL
41
8
6
4
Descrizione
Description
DO NOT USE
16
Test sicurezze
Closing safety contact
Sicurezza in chiusura
Sicurezza in apertura
Opening safety contact
Chiusura
Closing
Apertura
Opening
+
24 V
0,36 A
-
1
0
3