Technical Data; Main Specifications - Pando PGA-4490 Instrucciones Y Consejos Para El Uso, La Instalación Y El Mantenimiento

Placas de coccion de encastre gas de vitroceramica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DESCRIPTION
One electronic board allows for controlling a gas cooktop with 4-5 burners.
This product operates with Brahma VPC01 valves that enable adjustment of each burner power separately, using methane or
liquefied petroleum gas.
The appliance is also equipped with user interface having a seven-segment display and touch panel.

MAIN SPECIFICATIONS

Main specifications are given below.
• A display with 7 red-colored segments and LCD displays for indicating power level of each individual burner, as well as for
time and settings indication.
• Touch panel with 15 sensor zones for selecting power level for each burner individually, setting, control panel lock, and
switching on/off.
• Five 24 VDC outputs for Brahma VPC01 modulating valves.
• 24 VDC output for main Brahma VPC01 valve after discharge pipe.
• RS232 interface for appliance testing.
• Five Faston inputs for flame sensor electrodes of five burners.
• Output for 100-240 VAC igniter control.
• Control of pre-programed modulation levels in FLASH memory.
• Option to control two modulation tables (G20 and G30).
• Built-in procedure for minimum power level adjustment of each appliance burner.
• Power supply board designed using switching technology.
• Day clock in 24 h format.

TECHNICAL DATA

Power supply:
Frequency:
Power consumption:
Consumption in standby mode:
Switched-on transformer output contacts:
Sensor electrodes connection:
Operating temperature:
Protection class:
EN298 classification code:
characteristics
Maximum length of external cables:
Flame control
Flame sensor design uses the flame rectification process.
Minimum ionization current:
Maximum ionization current: (supply voltage 264 V
Recommended ionization current:
Maximum cable length:
Minimum electrode and measuring cable insulation resistance with earthing:
Maximum electrode stray capacitance:
Maximum short-circuit current
TIME
- wait time (TW):
- safety time (TS):
- response time in case of flame extinction:
- transition waiting or transition ventilation time:
- waiting time for interlock triggered by uncontrollable flame:
- ignition preparation time:
- ignition attempts number:
TECHNICAL DATA
Special
Description
Atmospheric monitor
Main burner direct ignition
Cycle repeat
Nonvolatile interlock
Setting time
Non-continuous operation
RMS
100-240 VAC ±10 %
50-60 Hz
92 VA
< 1 W
100–240 VAC ±10 % – 250 mA – cosφ = 0.4
2.8 x 0.8 mm Faston
-10 °C +85 °C
IP 00
)
1 s
4 s
3 s
10 s
10 s
0 s
3
25
Code
A
M
C
L
X
N
≤ 1 m
0.2 µA DC
4.6 µA DC
3-5 times the minimum current
1 m
≥ 50 MΩ
≤ 1 nF
≤ 200 µA
A C
(per EN 30-1-4)