Diagnostics Cycle Chart

It is recommended to take note of, then clear the Fault History before running the Diagnostic Cycle.
When the Diagnostic Cycle is executed the display will show "Activated Diagnostic Cycle".
NOTE: The basket must be empty during this test. Some loads will not be available on all models.
Step
Washer Function
Warm water fills through the
1
Detergent valve
Hot water fills through the
2
Detergent
valve
Cold water fills through the
3
Detergent
valve
Water fills through the Fabric
4
Softener
valve
Water fills through the OXI
5
valve*
6
Drain pump turns on
7
Recirculation pump turns on*
Drain and recirculation pump
8
turn on**
9
Lid locks
10
Shift to Wash
11
Wash fast
12
Shift to Spin
13
Spin up to 500 RPM then stop
14
Shift to Agitate
15
Agitate fast
16
Unlock lid
Total test time in minutes is expected to be between 4-7 minutes.
Steps 1-5 will display FILLING. Steps 6-8 will display RINSE. Steps 9-11 & 14-15 will display WASHING. Steps 12-13 will display SPIN. Step 16 will
display DONE.
*On models without bleach/oxi valve, and/or recirculation pump, steps 5, and 7 will be skipped.
**On models without recirculation pump, only drain will activate for the duration of step 8.
DO NOT REMOVE OR DESTROY
FOR SERVICE TECHNICIAN'S USE ONLY
If no water, use service component activation to manually turn on and test the hot and
cold water valves.
If no water, use service component activation to manually turn on and test the valve.
If no water, use service component activation to manually turn on and test the valve.
If no water, use service component activation to manually turn on and test the softener
valve.
If no water, use service component activation to manually turn on and test the OXI valve.
If water is not draining, use service component activation to manually turn on and test the
drain pump.
If the pump does not turn on or water level does not drop, use service component
activation to manually turn on and test the recirculation pump.
If water is not being drained or recirculated, use service component activation to
manually turn on and test the drain and recirculation pump.
Lid must be closed. If lid does not lock, use service component activation to manually
test the lid lock.
Use service component activation to manually test the shifter.
Use service component activation to manually test the motor.
Use service component activation to manually test the shifter.
Use service component activation to manually test the motor.
Use service component activation to manually test the shifter.
Use service component activation to manually test the motor.
If lid does not unlock, use service component activation to manually test the lid lock.
Recommended Procedure
Est. Time (s)
60
5
5
5
5
15
15
>30
5
30
5
30
200
30
10
5
7