4.3.10. "Pump stop": pH pump stop over feed alarm (pH - PH/ORP models)
The pH pump stops rotating if the pH setpoint has not been reached after a given time, resulting in the display of an
alarm. By default, this programmed safety time is 60 minutes. To adjust it (minimum value: 1 min - maximum value:
120 min):
• From the Configuration/Pump stop mode, press
• Press
to switch to "ON". The injection time flashes.
• Press
or
to adjust this value.
• Press
to confirm.
4.3.11. "Auto Cl mV": Automatic ORP regulation (pH/ORP models)
This mode is activated by default on pH/ORP models only. Production stops when the setpoint is passed. To deactivate
the automatic mode:
• From the Configuration/Auto Cl mV mode, press
• Press
to activate it ("OFF").
• Press
to confirm.
4.3.12. "Cl EXT": Slave mode
• Ensure that these appliances are properly connected to the power supply in accordance with
the regulations in force and are protected by a circuit breaker (filtration unit).
Slave mode transfers control over the chlorination function to an external controller (ORP or ppm control). Once the
external controller is correctly connected to the connection point (see § "2.6.2. Detail of connections"), activate the
Slave mode:
• From the Configuration/Cl EXT auto mode, press
• Press
to activate it ("ON").
• Press
to confirm.
29
: "OFF" flashes
: "ON" flashes.
: "OFF" flashes.