4.3.2. Appliance information
Show the appliance model
• Press
for 5 seconds.
The appliance model is displayed on the screen
(platform version and g/h power).
4.3.3. Displaying and resetting the number of operating hours of the cell or the pH pump
• Press
for 5 seconds to see the "Appliance model" display.
• Press once on
to view the number of hours the cell has been in use ("Config Cell" is displayed) or press 3 times
on
to view the number of hours the pH pump has been in use ("Config" is displayed).
• The "h" value corresponds to the number of hours the cell has been in use since the last reset. Press twice on
to reset the value.
• Press
to switch to the "H" value: this corresponds to the total number of operating hours and cannot be reset.
• Press
to exit.
4.3.4. "Reverse direct": Reversal adjustment for cell cleaning
The polarity reversal principle eliminates scaling that has deposited on the electrodes by reversing the electrical power
at a specified time.
• The hardness of the water varies depending on the geographical region concerned (water hardness = TH).
• In order to protect the electrodes from scale build-up (which reduces the efficacy of the electrolysis reaction), the
polarity reversal time can be adjusted.
By default, the cycle is reversed every 2 hours. You may increase polarity reversal time to 3, 4 or 7h if water hardness
is below 200 ppm (20°f). To set this duration:
• In the Configuration/Reverse Direct mode, press
duration flashes.
• Press
or
to choose between 2h, 3h, 4h or 7h (or "tSt" test mode).
• Press
to confirm the duration.
Show the current software version
• Press
for 5 seconds then press
ware version is displayed on the screen.
to change the duration of polarity reversal. The displayed
. The soft-