2.3 I Installing the sensors
• Never wipe the sensor using a cloth or paper tissue, as this may damage it.
• A badly-installed sensor may give false readings and cause inappropriate operation of the appliance.
Neither the manufacturer nor the appliance shall be liable in this event.
• Carefully unscrew the protection tube from the sensor (
winter.
• Rinse the end of the sensor with tap water and shake off excess water (
• Loosen the nut fixed to the sensor holder (
• Install the pH sensor and/or the ORP sensor (supplied) in the sensor holder so that the sensor located at the end
of the holder is always submerged in the water flowing through the piping(
tangled.
• To avoid damage, sensor end must be located in the center of the pipe, not further.
• The sensor must always be installed vertically, or where necessary, at a maximum angle of 40°(
• Once the sensor is installed it can be connected to the BNC socket on the control box, see § "2.5.2. Connecting the
control box" ).
• The sensor must then be calibrated, see § "4.4 I Calibrating the sensors (pH or pH/ORP models)".
pH
(pH & pH/ORP, depending on model)
). Keep the protection tube for storing the sensor over
).
ORP
).
). Ensure that the cable is not
40°
).