4.3.7. "Cover": Connecting a pool cover
If the pool is equipped with a compatible electric cover, it can be connected to the appliance in order to automatically
reduce chlorination when it is closed: this is the "Cover " mode. It is then automatically activated when the pool cover
is closed, and chlorination resumes at the level determined by the programming on opening the compatible electric
pool cover.
Check that the cover is compatible and is connected to the appliance on the low-voltage circuit, see § "2.6 I
Connecting auxiliary devices".
This mode is deactivated by default. To activate it and configure the production:
• From the Configuration/Cover mode, press
duction (configurable between 10% and 90%).
• Press
to confirm.
Recommendations for use:
• Adjust the production percentage to between 10% and 30%.
• You may let ORP regulation manage chlorination instead of pool cover mode if water stay warm when
pool cover is closed.
4.3.8. "Intelligent pH" mode
The "Intelligent pH" mode is used to adjust the pH more precisely: it reduces production as the setpoint is
approached, thus reducing wider fluctuations in pH levels.
This mode is activated by default. To deactivate it:
• From the Configuration/Intelligent pH mode, press
• Press
to deactivate it ("OFF").
• Press
to confirm.
4.3.9. "Ini pH": Initialisation of pH regulation
This mode allows the pH measurement to stabilise over a certain time at each start-up, before starting to dose (if
necessary). The initialisation time can be set to 0, 1, 2 or 4 minutes.
This mode is deactivated by default. To activate it:
• From the Configuration/Ini pH mode, press
• Press
to activate ("ON") and to configure the initialisation time.
to confirm.
• Press
• It is advised to enable this feature and set it to "1 min" to prevent unwanted pH corrective product
injection upon each filter pump startup.
then
to activate or configure the desired percentage of pro-
: "ON" flashes.
: "OFF" flashes.
EN
28