ENGLISH
Troubleshooting
When an error occurs, the code displays in the form of a blinking red and/or green light on the main
bezel of the machine. The different errors can be interepreted by watching the sequences of the blinking
lights. These blinking light codes are outlined in the "Issue/Error Code" column of this troubleshooting
guide.
Issue/Error Code
Alternating Red and Green Lights (Error code 1)
2 Red blinks, pause, repeat (Error code 2)
3 Red blinks, pause, repeat (Error code 3)
2/25/16
Problem
Media jam
Sensor failure
PLM location sensors not
working
Solenoid valves not firing
One or both of the dies are
stuck open or closed
Die location sensors not
working
Troubleshooting 13
Solution
• Open the rear door and
the die module.
• Clear the jam.
• Close the rear door and
die module
• Open access door to
reset error.
• Close cover.
If problem persists, contact
Brady Technical Support
• Open access door to
reset error.
• Close cover.
If problem persists, contact
Brady technical support
• Open access door to
reset error.
• Close cover.
If problem persists, contact
Brady technical support
• Ensure dies are free of
debris.
• Reinstall both dies and
ensure proper fit.
If problem persists contact
Brady technical support
Call Brady Technical Support
for assistance
BSP45 User's Manual