6.1.3 Stroke/pulse signal / pre-empty signal / error signal
Socket 3
Electrically isolated output for stroke/pulse signal or pre-empty signal and error signal.
Socket 3
Pin
Assignment
1
Error signal contact
2
Stroke/pulse signal or pre-empty signal contact
3
Stroke/pulse signal or pre-empty signal contact
4
Error signal contact
6.1.4 Remote on/off / contact input / current input
Socket 4
For the remote on/off input and contact input or current input.
If the remote on/off and contact inputs are to be used at the same time, wire 1 is assigned twice.
For the connection of one cable, use a plug adapter
with simple cable entry, for the connection of two
Caution
cables, use a plug adapter with double cable entry,
otherwise the protection will be lost!
Socket 4
Pin
Assignment
1
GND
2
Current input
3
Remote on/off input
4
Contact input
6.1.5 Empty signal only / pre-empty and empty signal
Socket 5
For the empty signal only or pre-empty and empty signal input.
The suction lines with empty signal or pre-empty and empty signal are pre-assembled with a plug for socket 5.
Socket 5
Pin
Assignment
1
Pre-empty signal
2
Empty signal
3
GND
6.1.6 PROFIBUS (optional)
Socket 6
Socket 6 for PROFIBUS is only used when the PROFIBUS option is selected.
For pumps with PROFIBUS option, please refer to the separate "PROFIBUS-DP" manual provided.
18
Cable
Wire colour
Brown
White
Blue
Black
Cable
Remote on/off
Wire colour
input
Brown
x
White
Blue
x
Black
Empty signal
x
x
Used for
Stroke/pulse signal /
Error signal
pre-empty signal
x
x
Used for
Contact input
+/- current input
x
x
Used for
Pre-empty signal
x
x
x
x
-
+