Festo 404-1 System Instrucciones De Utilizacion página 23

Distribución pro-unión-medición pro-clasificación en línea
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Digital (XG3)
Function
SysLink
I0
13
I1
14
I2
15
I3
16
I4
17
I5
18
I6
19
I7
20
Q0
1
Q1
2
Q2
3
Q3
4
Q4
5
Q5
6
Q6
7
Q7
8
24 V A
9+10
24 V B
21+22
GND A
11
GND A
12
GND B
23+24
Cable jumpers are connected from emergency stop to bit 1.5 for all PLC EduTrainer
universal standard MPS versions.
© Festo Didactic 8150266
404-1 System, Distributing Pro-Joining-Measuring Pro-Sorting Inline – Operating instructions
Color
Designation
Gray-pink
Gate valve magazine 3 retracted
Red-blue
Gate valve magazine 3 advanced
White-green
Magazine 3 empty
Brown-green
Activate magazine 3
White-yellow
Brown-yellow
White-gray
Gray-brown
White
Advance gate valve magazine 3
Brown
Magazine 3 activated
Green
Yellow
Gray
Pink
Blue
Red
Black
24 V supply for outputs
White-pink
24 V supply for inputs
Brown-pink
0 V power supply for outputs
Purple
0 V power supply for outputs
White-blue
0 V power supply for inputs
23

Publicidad