IO-Link
Port
Components
1
Valve manifold measuring
module
2
Displacement sensor
3
Indicator light
In the case of IO link, all signals are transmitted via an IO link multi protocol module,
which addresses the signals with different protocols depending on the controller.
•
Siemens PLC: ProfiNet,
•
Allen Bradley PLC: Ethernet IP,
•
Codesys PLC: IO link
© Festo Didactic 8150266
404-1 System, Distributing Pro-Joining-Measuring Pro-Sorting Inline – Operating instructions
Function
Rotary cylinder to the measurement table
Rotary cylinder to the second module
Lift gripper
Open gripper
Advance measuring cylinder
Measuring cylinder position
Measurement result indication
Reference designation
-MB1
-MB2
-MB3
-MB4
-MB5
-BG6
-PF1
29