Terminal Assignment Table, Joining Station - Festo 404-1 System Instrucciones De Utilizacion

Distribución pro-unión-medición pro-clasificación en línea
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

404-1 System, Distributing Pro-Joining-Measuring Pro-Sorting Inline – Operating instructions

7.3 Terminal assignment table, Joining station

Digital (XG1)
Function
SysLink
I0
13
I1
14
I2
15
I3
16
I4
17
I5
18
I6
19
I7
20
Q0
1
Q1
2
Q2
3
Q3
4
Q4
5
Q5
6
Q6
7
Q7
8
24 V A
9+10
24 V B
21+22
GND A
11
GND A
12
GND B
23+24
Analog
Function
D-SUB-15
AI0
8
24
Color
Gray-pink
Red-blue
White-green
Brown-green
White-yellow
Brown-yellow
White-gray
Gray-brown
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
Black
White-pink
Brown-pink
Purple
White-blue
Color
Cable jumpers are connected from emergency stop to bit 1.5 for all PLC EduTrainer
universal standard MPS versions.
Designation
Workpiece at start of conveyor (1)
Workpiece at intermediate conveyor position (1)
No workpiece at end of conveyor (1)
Workpiece orientation not correct, digital
Workpiece at start of conveyor (2)
No workpiece at end of conveyor (2)
Conveyor belt (1) forward
Conveyor belt (1) backward
Advance feed separator
Retract stopper
Conveyor belt (2) forward
Conveyor belt (2) reverse
24 V supply for outputs
24 V supply for inputs
0 V power supply for outputs
0 V power supply for outputs
0 V power supply for inputs
Designation
Workpiece orientation not correct, analog
© Festo Didactic 8150266

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8150260

Tabla de contenido