Technical Data; General Data - Festo 404-1 System Instrucciones De Utilizacion

Distribución pro-unión-medición pro-clasificación en línea
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

404-1 System, Distributing Pro-Joining-Measuring Pro-Sorting Inline – Operating instructions

7 Technical data

7.1 General data

Parameter
Operating pressure
Operating voltage
Digital inputs/outputs
Inputs:
Outputs:
Analog inputs/outputs
Inputs:
Outputs:
Digital input/outputs via IO-Link gateway (Distributing Pro station)
Inputs:
Digital input/outputs via IO-Link DA interface (Joining station)
Inputs:
Outputs:
Digital input/outputs via IO-Link gateway (Measuring Pro station)
Inputs:
Outputs:
Digital inputs/outputs via RFID gateway (Sorting Inline station)
Inputs:
Outputs:
Electrical connection
Pneumatic connection
Compressed air consumption at 600 kPa (continuous cycle)
Dimensions
Subject to change
20
42 (15+14+6+7)
23 (9+4+6+4)
2
1
3
4
4
1
6
1
1
Value
600 kPa (6 bar)
6x 230 V "IEC power cable"
Each station 24 V DC, 4 A, ≤ 100 W output power,
SELV/PELV limited power supply (LPS)
Max. 24 V DC
Max. 2 A per output
Max. 4 A total
0 ... 10 V DC
or ±10 V DC
24 V DC
Max. 0.5 A per output
Max. 2 A total
24 V DC
Max. 0.5 A per output
Max. 2 A total
24 V DC
Max. 0.5 A per output
Max. 2 A total
24 V DC
Max. 0.5 A per output
Max. 2 A total
Standard power plug
RJ-45 network connection
Plastic tubing with 6 mm outside diameter
10 l/min.
2100 mm x 700 mm x 1705 mm
© Festo Didactic 8150266

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8150260

Tabla de contenido