Room Ventilation; Assembly Appliances In Banks - Angelo Po 091FR1ID Manual De Uso Y Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ROOM VENTILATION

The room where the appliance is installed must
have air inlets to ensure that the appliance can op-
erate correctly and provide the necessary air ex-
change in the room itself.
The air inlets must be of appropriate size and must
be protected by gratings and placed so that they
cannot be obstructed.
The appliance is delivered with some compo-
nents dismantled and they have to be fitted
during installation. Specifically, the floor-
mounted feet must be fitted (A).
LEVELLING
Adjust the floor-mounted feet (A) to level the appli-
ance.
IT
GB

ASSEMBLY APPLIANCES IN BANKS

DE
To assemble appliances in banks (side by side)
proceed as described below.
FR
1 - Undo the screws (A) and remove the control
panels (B).
ES
2 - Apply masking tape to the edges to be placed
side by side.
3 - Apply food-approved sealant to the edges to be
placed side by side.
4 - Place the appliances side by side.
5 - Connect the appliance using the screws and
nuts (C-D).
6 - Remove the excess sealant and the masking
tape.
7 - Apply the sealant to the inside of the lid (E), and
fit it to cover the fixing zone.
8 - Replace the control panels (B) on completion of
the operation.
English
INSTALLATION OF DISMANTLED PARTS
A
A
C
- 22 -
IDM-39619401500.tif
IDM-39619401600.tif
B
E
D
IDM-39619401700.tif

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

191fr2id

Tabla de contenido